#$&*
Phy 202
Your 'timer program' report has been received. Scroll down through the document to see any comments I might have inserted, and my final comment at the end.
** TIMER program_labelMessages **
** **
approximately 45 minutes (includes time spent playing around on excel with the data on the last question)
** **
DO NOT COPY THE LINES ABOVE THIS ONE. JUST FILL THOSE LINES IN WHEN YOU SUBMIT YOUR RESULTS AT THE END OF THIS FORM.
•Follow the instructions, fill in your data and the results of your analysis in the given format.
•Regularly save your document to your computer as you work.
•When you have completed your work:
Highlight the contents of the text editor, and copy and paste those contents into the indicated box at the end of this form.
Click the Submit button and save your form confirmation.
This experiment is self-explanatory. Student report time of completion ranging from 10 minutes to 1 hour, with 30 minutes being the most typical.
Downloading and/or running the TIMER program
If you have a Macintosh computer the preferred timer.exe program might not work (it will if your computer has a Windows emulator), but the alternative Java applet should work just fine.
timer.exe
The program timer.exe should be downloaded to your hard drive and/or flash drive so you have access to it whenever you need it.
There is an alternative Java applet (see the heading timer java applet below) , but the .exe option is preferable. It is worth 15 minutes of effort to get the program working on your hard drive, after which you will have it and won't need Internet access to run it. It will start up instantly, it runs in a small window, and it has the ability to file your data. However if you can't get it working in 15 minutes with the instructions given below, just move on the the Java version.
To use the Windows version:
If you are using a Windows PC, or a Mac with Windows emulator, first take a few seconds to run the program q a prelim. As soon as the form opens on your screen, you can close it. Nothing needs to be submitted. The first thing this program does is to create the c:\vhmthphy folder on your hard drive. As an alternative you can also create a c:\vhmthphy folder.
The timer.exe program opens in a small window and can be run side-by-side with other windows applications on your computer (just size the second window so it leaves room for the Timer program).
Run the program now. If it fails to work then try the following, in order:
•If you got the Run-time Error 76, it can be corrected by the step given earlier. That instruction is repeated below:
Run the program q a prelim. As soon as the form opens on your screen, you can close it. Nothing needs to be submitted. The first thing this program does is to create the c:\vhmthphy folder on your hard drive. As an alternative you can manually create this folder.
•If this doesn't work, follow the link COMDLG32 to access simple instructions for fixing the problem. Then run timer.exe .
To use the Java version:
Windows users:
The Java applet does require that the Java Runtime Environment be installed. Almost every Apple computer, and most Windows computers, will have this environment installed. If your computer will not run the Java applet, the installation is simple and quick. If you search under 'Java Runtime Environment', using any search engine, you will find information on the Java Runtime Environment and on the installation. You should satisfy yourself that you are downloading from a verifiable, trusted source.
Mac users:
Apple supplies their own version of Java. Use the Software Update feature (available on the Apple menu) to check that you have the most up-to-date version of Java for your Mac.
should check the Apple site for the Software Update feature (available on the Apple menu) to check that you have the most up-to-date version of Java for your Mac.
The Java Applet at the link Timer-Java will work fine for the current experiment, and will do just about everything the timer.exe program will do. The Java applet has a few more or less minor inconveniences and one that's not quite as minor:
•You can't put the Java applet on your hard drive or flash drive, so you have to pull it off the Web every time you want to use it.
•The applet won't file your data. However it will let you copy and paste your data into a text editor.
•If your machine doesn't run Java applets, you would have to set it up to do so (just search the web under 'Java Runtime Environment', which is free and installs easily). This software is pretty standard, and is already installed on most machines.
If the Timer-Java program won't run on your computer you might need to set Java to give it the necessary permissions. The instructions for doing so are as follows:
1. navigate to the java control panel by searching java from the windows search (start button on win 7) (move cursor to upper right corner to display search icon on win 8)
2. select configure
3. go to the security tab on the control panel.
4. select the edit site list option
5. select add and copy/paste the url of the page
6. apply settings
If these programs don't work there is a program at
• http://tools.arantius.com/stopwatch
that provides similar output. However the format of the output has its disadvantages, one being that the output is given in hour-minutes-seconds, a format that isn't compatible with, say, many spreadsheets. This would add significant editing time to some activities.
Operating the TIMER program
It is easy to operate the Timer program. All you have to do is click on the button labeled Click to Time Event.
Click that button about 10 times and describe what you see.
#$&*
Now click on Initialize or Reset the Counter, which will clear all the data from the timer window. Click the mouse as fast as you can until the TIMER window fills up. Be sure you get at least 20 time intervals.
If you miss a click, try again. Keep trying until you get at least 20 quick-click intervals without a missed or delayed click.
Copy your data starting in the next line:
1 57.33594 57.33594
2 57.48047 .1445313
3 57.60547 .125
4 57.75391 .1484375
5 57.87891 .125
6 58.01563 .1367188
7 58.16406 .1484375
8 58.29688 .1328125
9 58.4375 .140625
10 58.58203 .1445313
11 58.69531 .1132813
12 58.84375 .1484375
13 58.96875 .125
14 59.10156 .1328125
15 59.23828 .1367188
16 59.39844 .1601563
17 59.53516 .1367188
18 59.67188 .1367188
19 59.82422 .1523438
20 59.94531 .1210938
21 60.07813 .1328125
22 60.25391 .1757813
23 60.41406 .1601563
#$&*
You got at least 20 time intervals. Based on your data what was the average of the first 20 time intervals? Note that you could get this average by averaging the first 20 intervals. My first few intervals were .15625, .15625, .1875, .171875, etc; I could just add up the first 20 intervals and divide by 20 to get the average. However there is an easier and quicker way to get the result, so use the easier way if you can. NOTE: Spreadsheet calculations and other methods that disguise the process of finding the average are not valid answers to this question. Spreadsheets are perfectly legal for most data analysis, but not in this experiment.
Give your result, number only, in the first line, and starting in the second line explain how you got it.
average of quick-click intervals:
0.13711
explanation:
To get the interval average without adding all the numbers and then dividing, I calculated the total time for twenty clicks, by taking the first click start time (57.33594), subtracting it from the time after the 20th click (60.07813) to get 2.7429, then divided this result by 20.
#$&*
When I did this activity the first few lines of my data were as follows:
event number clock time time interval
1 11.67188 11.67188
2 11.875 0.203125
3 12.0625 0.1875
4 12.20313 0.140625
5 12.375 0.171875
6 12.54688 0.171875
7 12.73438 0.1875
8 12.92188 0.1875
9 13.10938 0.1875
10 13.28125 0.171875
11 13.4375 0.15625
(The Online Stopwatch program gives output that looks like the following:
Lap #
This Lap
Running Total
1 00:00:00.231 00:00:00.231
2 00:00:00.200 00:00:00.431
3 00:00:00.200 00:00:00.631
4 00:00:00.177 00:00:00.808
5 00:00:00.184 00:00:00.992
When copied into Notepad it comes out looking like this:
Lap # This Lap Running Total
1 00:00:00.231 00:00:00.231
2 00:00:00.200 00:00:00.431
3 00:00:00.200 00:00:00.631
4 00:00:00.177 00:00:00.808
5 00:00:00.184 00:00:00.992
6 00:00:00.241 00:00:01.233
16 00:00:00.178 00:00:03.327
If you search and replace 00:00: with four spaces you get
Lap # This Lap Running Total
1 00.231 00.231
2 00.200 00.431
3 00.200 00.631
4 00.177 00.808
5 00.184 00.992
6 00.241 01.233
which is usable.)
With my data, it looks like the same intervals keep popping up. For example .1875 seconds occurs 5 times out of the first 10 intervals, .171875 seconds occurs three times, and .203125 seconds, .140625 seconds and .15625 seconds each occur once. With the Online Stopwatch program, we find that 0.200 seconds gets repeated once in 6 intervals.
A frequency distribution for my original time intervals would be as follows:
time interval frequency
,140625 1
.15625 1
.171875 3
.1875 5
.203125 1
What different time intervals did you observe in your first 20 intervals, and how many times did each occur? List below the different time intervals you observed and the number of times each occurred. List from the shortest to the longest interval, and use a comma between the time interval and its frequency. For example my data above would be listed at
.140625, 1
.1565, 1
.171875, 3
.1875, 5
.203125, 1
The above list is called a frequency distribution. Be sure you make note of this terminology.
Your list should be in exactly the above format, with no other symbols or characters.
Your list (i.e., your frequency distribution):
.1445313, 2
.125, 3
.1484375, 3
.1367188, 4
.1328125, 3
.140625, 1
.1132813, 1
.1601563, 1
.1523438, 1
.1210938, 1
#$&*
You are welcome make any comments or ask any question about the process so far.
#$&*
On the 10 intervals I've shown you, do you really think I managed to get a time of .1875 seconds, accurate to 4 significant figures, on half of the intervals? If you do, I'm grateful for your confidence but I'm just not that good. No human being has that much neurological and muscular control.
So why do you think the TIMER program reported that time so frequently? Why weren't there times like .1830 seconds, or .1769 seconds? Does this mean that the TIMER program is flawed? Does that mean it's useless?
Why did the TIMER report .1875 seconds multiple times; your conclusions about the program:
I believe the timer program reported multiple times due to the accuracy of the program, if multiple times were within whatever difference that is too small for the program to measure, then it will see the times as the same. I would not say the timer prgoram is flawed, but when using the program we need to understand the limitations of the measurement it can provide. FOr many things, the time measurement provided would be useful, for things that require a greater degree of accuracy, a different tool may be needed.
@&
Very good.
*@
#$&*
Here are a few more lines of data, with an added column showing the difference between each time interval and the next.
clock time time interval difference from one time interval to next
9 13.10938 0.1875 -0.01563
10 13.28125 0.171875 -0.01563
11 13.4375 0.15625 0.03125
12 13.625 0.1875 -0.01563
13 13.79688 0.171875 0.015625
14 13.98438 0.1875 0.015625
15 14.1875 0.203125 -0.03125
16 14.35938 0.171875 -0.01563
17 14.51563 0.15625 0.03125
Take a good look at that last column and tell us what you see in those numbers, and what this tells you about the TIMER program:
It looks like the time interval of 0.015625 may be the smallest increment the program can measure. This is the smallest number on the list, and other larger numbers are multiples 0.015625, for example 0.03125. My assumption is that 0.01563 is probably a rounding function of the program and not indicative of the program being able to measure a 0.000005 second difference, since this is not shown anywhere else in the data.
@&
Once more, very good.
*@
#$&*
Now initialize the TIMER once more, and take a series of 10 relaxed breaths. Every time you start to inhale, hit the TIMER button.
My results for the first 7 complete breaths are as follows:
series of relaxed breaths
event number clock time time interval difference between time interval and next
1 1569.734 1569.734
2 1582.75 13.01563 0.32812
3 1596.094 13.34375 3.90625
4 1613.344 17.25 2.70313
5 1633.297 19.95313 1.35937
6 1654.609 21.3125 4.23438
7 1680.156 25.54688 2.15625
8 1707.859 27.70313
I didn't go on because the time between my breaths kept increasing, and I was afraid if I relaxed any more I might stop breathing altogether. It's going to take either more statistical analysis to determine whether that's a real danger, or a little common sense.
Report your results by just entering your time intervals, one to each line, in the box below. If I was entering my results I would enter
13.01563
13.34375
17.25
19.95313
21.3125
etc.
Enter your results in the same format:
7.173828
10.09961
9.804688
11.91406
14.78125
13.64453
13.36328
13.23633
13.32422
12.55078
#$&*
If you have any comments please insert them here
#$&*
Most likely you did not observe the same exact time interval twice, and if you did it did not happen nearly as often as when you did the fact clicks.
Why do you think this is exactly what we would expect?
I think this is because the breathe interval measurement is a much larger measurement, and when using a relatively small time increment for measuring, we would not expect to see so many alike intervals.
#$&*
Which of the following statements do you think is the most accurate?
a. The TIMER program (or the Java TIMER or the Online Stopwatch -- specify which) is capable of determining the time between two events accurately to within about .1 second.
b. The TIMER program (or the Java TIMER or the Online Stopwatch -- specify which) is capable of determining the time between two events accurately to within about .01 second.
c. The TIMER program (or the Java TIMER or the Online Stopwatch -- specify which) is capable of determining the time between two events accurately to within about .001 second.
d. The TIMER program (or the Java TIMER or the Online Stopwatch -- specify which) is capable of determining the time between two events accurately to within about .0001 second.
Enter your answer and your reasoning below:
The TIMER program is capable of determining the time between two events accurately to within about .01 second, based on my earlier observation that 0.015625 is the smallest measurement we recorded.
#$&*
If you don't have a spreadsheet you should be able to easily access a free spreadsheet in order to do this last step. If you don't have time right now you can do this part later, and submit just a copy of this question and your response, using the Question Form .
If you don't know what text editor comes with your device (for Windows this would be Notepad), you should simple search the Web under 'text editing for ****' where **** is your device.
Note that this course is not intended to be run from a handheld device. Screens are too small to clearly see the necessary amount of content. However if either version of the TIMER runs on your handheld device and that device allows you the necessary functionality, it's fine to use it.
Note that the TIMER.exe program can save your data in a format that can be read by a spreadsheet (the TIMER applet cannot do so). This will be very handy in the future, so take a minute and do the following:
If you are using the TIMER.exe program:
1. Click on the button at the lower right of the TIMER form, entitled Click to File Data.
2. A box will pop up allowing you to include an identifying message. You should generally choose to include such a message; for the data presently on your timer that might be 'series of regular breaths time at beginning of inhalation' or something similar. Type in whatever you think would serve as a good identifier for this data and OK that box.
3. A typical Save As window will appear. Decide where to save your data and what to call it, and proceed to save it. The program will save the file as a comma-delimited text file.
4. Open your spreadsheet program (typically Excel) and choose File > Open. Browse to the folder in which you just saved your data. Below the File Name line will be a File Type line; set this either to Text Files or All Files so your file will appear. Open it.
5. A series of windows will typically appear. In the first window make sure the file type chosen is Delimited, the proceed to the next window.
6. In the second window you will see a series of checkboxes; check the one entitled Comma, in order to select the comma-delimited file, then just click on Finish.
If you are using the TIMER applet you can't do Steps 1-3. In this case:
Copy the contents of the program to a text file, using copy-and-paste. Just highlight the contents of the box, copy and past into a text file. Save the text file using any filename you wish. Then proceed with steps 4-6 above.
Your data should appear in your spreadsheet, and can be manipulated as in any spreadsheet.
Copy a few lines of the data from your spreadsheet below, and indicate what spreadsheet you are using:
1 17.83594 17.83594
2 25.00977 7.173828
3 35.10938 10.09961
4 44.91406 9.804688
5 56.82813 11.91406
6 71.60938 14.78125
7 85.25391 13.64453
8 98.61719 13.36328
9 111.8535 13.23633
10 125.1777 13.32422
11 137.7285 12.55078
12 150.0742 12.3457
Using excel (office 2010)
#$&*
Your instructor is trying to gauge the typical time spent by students on these experiments. Please answer the following question as accurately as you can, understanding that your answer will be used only for the stated purpose and has no bearing on your grades:
•Approximately how long did it take you to complete this experiment?
approximately 45 minutes (includes time spent playing around on excel with the data on the last question)
@&
Very good.
Note that .015625 is 1/64.
*@