Your work on timer program has been received. Scroll down through the document to see any comments I might have inserted, and my final comment at the end.
Your General Comment
On the last question, I was supposed to click to file data and it would not work. The program told me to simply copy and paste my work. Sorry for the inconvenience. I have still not received my book and DVD's. I ordered them from the bookstore last week and every time I call, they tell me a new date that they shipped out. Hopefully I will get them soon so that I do not fall behind:)
Describe what you see on your first 10 clicks
I se a list of 2 columns with ten numbers in each column.
Your TIMER data from 20 fast clicks
1 137.0313 137.0313
2 137.1797 .1484375
3 137.3125 .1328125
4 137.4609 .1484375
5 137.6016 .140625
6 137.75 .1484375
7 137.8906 .140625
8 138.0391 .1484375
9 138.1875 .1484375
10 138.3359 .1484375
11 138.4922 .15625
12 138.6484 .15625
13 138.8125 .1640625
14 138.9609 .1484375
15 139.1172 .15625
16 139.2734 .15625
17 139.4297 .15625
18 139.5703 .140625
19 139.7344 .1640625
20 139.8906 .156
21 140.0234 .1328125
Your average time interval for 20 time intervals
0.1492
I added all of the intervals together and divided by 20.
Your frequency distribution for the 20 time intervals (interval, number of times it was observed)
.1328125, 2
.140625, 3
.1484375, 7
.15625, 6
.1640625, 2
Your general comment to this point
Why did you observe only certain time intervals?
I dont think that it is useless, but im not sure why it would have repeat intervals at such precision.
What did you see when you looked at the differences between time successive time intervals?
The differences are also repeditive. The timer program has certain intervals where it stops. It is not able to determine such precise intervals.
Your time intervals for 7 complete breaths:
3.171875
2.882813
3.476563
3.148438
3.359375
3.328125
3.234375
3.273438
3.414063
Your general comment to this point:
Why did you rarely, if ever, observe that same time interval twice?
Since the time intervals were longer, the timer did not have to read the intervals with such great precision.
Do you think this program is accurate to .1 or .01 ...
I think that a is correct. The timer can only accurately determine the time between two events within about .1 second because at .01 seconds, the intervals begin to get repeditive.
Copy of a few lines of your spreadsheet from the TIMER program.
1 4584.094 4584.094
2 4587.266 3.171875
3 4590.148 2.882813
4 4593.625 3.476563
5 4596.773 3.148438
6 4600.133 3.359375
7 4603.461 3.328125
8 4606.695 3.234375
9 4609.969 3.273438
10 4613.383 3.414063
Your responses have been reviewed and everything looks good.