timer program

Your 'timer program' report has been received. Scroll down through the document to see any comments I might have inserted, and my final comment at the end.

Your General Comment

just reorienting myself....

Describe what you see on your first 10 clicks

I see two columns, on measuring the total time elapsed, and the other measuring the time interval between two clicks.

Your TIMER data from 20 fast clicks

3984375 .3984375

3 .7109375 .3125

4 1.007813 .296875

5 1.3125 .3046875

6 1.609375 .296875

7 1.914063 .3046875

8 2.210938 .296875

9 2.484375 .2734375

10 2.75 .265625

11 3.054688 .3046875

12 3.335938 .28125

13 3.679688 .34375

14 3.984375 .3046875

15 4.265625 .28125

16 4.585938 .3203125

17 4.882813 .296875

18 5.21875 .3359375

19 5.515625 .296875

20 5.84375 .328125

Your average time interval for 20 time intervals

.2922 seconds.

I took the total time and divided it by the total number of intervals.

Your frequency distribution for the 20 time intervals (interval, number of times it was observed)

.3984375, 1

.3125, 1

.296875, 1

.3046875, 3

.296875, 3

.3046875, 3

.296875, 2

.2734375, 1

.265625, 1

.3046875, 2

.28125,2

.34375, 1

.28125, 1

.3203125, 1

.296875, 2

.3359375, 1

.328125, 1

Your general comment to this point

Why did you observe only certain time intervals?

the timer program was rounding to .005. it is still more accurate than a hadwatch....

What did you see when you looked at the differences between time successive time intervals?

the last column tells YOUR inaccuracy. If you were measuring equal time intervals there would be the same time intervals throughout. thus zero difference in the time it takes to go between time intervals.

Your time intervals for 7 complete breaths:

Text1

1 0 0

2 4.096069 4.096069

3 8.863037 4.766968

4 12.65808 3.795044

5 17.84607 5.187988

6 21.44104 3.594971

7 28.56104 7.119995

8 32.36707 3.80603

9 35.21106 2.843994

10 39.22705 4.015991

Your general comment to this point:

Why did you rarely, if ever, observe that same time interval twice?

breathing is less regular than fast clicking. also, since the difference between breaths is longer, one would expect more accurate measurement.

Do you think this program is accurate to .1 or .01 ...

b. whenever events were closer than that, the user's click accuracy became a factor.

Copy of a few lines of your spreadsheet from the TIMER program.

my timer program doesn,t have those buttons.... I will look for another version to download

Your responses have been reviewed and everything looks good.

Please let me know if you have any questions related to this orientation assignment.