timer program

Phy 232

Your 'timer program' report has been received. Scroll down through the document to see any comments I might have inserted, and my final comment at the end.

** Your General Comment **

** Describe what you see on your first 10 clicks **

The timer produces 2 times. The first is how long the timer program has been open. The second is the time diff between when I clicked the time event button.

** Your TIMER data from 20 fast clicks **

1 131.4141 131.4141

2 131.6016 .1875

3 131.7734 .171875

4 131.9453 .171875

5 132.1172 .171875

6 132.2734 .15625

7 132.4297 .15625

8 132.6016 .171875

9 132.7734 .171875

10 132.9297 .15625

11 133.1016 .171875

12 133.2891 .1875

13 133.4453 .15625

14 133.6172 .171875

15 133.8047 .1875

16 133.9766 .171875

17 134.1641 .1875

18 134.3516 .1875

19 134.5391 .1875

20 134.7422 .203125

21 134.9453 .203125

** Your average time interval for 20 time intervals **

.176555

I added up the 20 numbers and divided by 20.

** Your frequency distribution for the 20 time intervals (interval, number of times it was observed) **

.15625, 4

.17185, 8

.1875, 6

.203125, 2

** Your general comment to this point **

** Why did you observe only certain time intervals? **

The timer averaged to the closest times that had been reported. All of the times were in intervals and not exact times.

** What did you see when you looked at the differences between time successive time intervals? **

The last column shows the difference between the time right before the interval. All of the differences are factors of .01563 and therefore the timer does in fact round.

** Your time intervals for 7 complete breaths: **

5.5313

3.4844

3.1093

3.5625

3.1211

3.625

2.9883

2.8711

3.5664

** Your general comment to this point: **

** Why did you rarely, if ever, observe that same time interval twice? **

No, I did observe the same interval twice. The breathing was not as regimented as the clicking was. The breaths were further apart than the clicking was.

** Do you think this program is accurate to .1 or .01 ... **

B. The clicking was very close together. However the times were accurate to about .01 second and then the rounding occurred.

** Copy of a few lines of your spreadsheet from the TIMER program. **

1 , 645.6406 , 645.6406

2 , 648.1719 , 2.53125

3 , 651.6563 , 3.484375

4 , 654.7656 , 3.109375

5 , 658.3281 , 3.5625

6 , 661.4492 , 3.121094

7 , 665.0742 , 3.625

8 , 668.0625 , 2.988281

9 , 670.9336 , 2.871094

10 , 674.5 , 3.566406

** **

15 minutes

** **

&#Your work looks very good. Let me know if you have any questions. &#